{"product_id":"tpmg-hygiene-temperatursensor-hart-mhy-ts","title":"TPMG Hygienic Temperature Sensor HART (MHY-TS)","description":"\u003cp\u003eThe \u003cstrong\u003eTPMG\u003c\/strong\u003e is a compact temperature sensor in a hygienic design with HART, manufacturer type Müller \u003cstrong\u003eMHY-TS\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eIt is the hygienic version of the same design platform: The process connection is \u003cstrong\u003eG1\/2\" in a hygienic design\u003c\/strong\u003e or an immersion probe, sensor tube, process connection and housing are continuously made of stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, the connector insert is always metal – plastic is not provided. It is designed for measuring points that are cleaned and where no plastic should be in contact with the medium. The system pressure is \u003cstrong\u003emax. 25 bar\u003c\/strong\u003e, the protection class \u003cstrong\u003eIP 65 \/ IP 68\u003c\/strong\u003e, the installation length 50 to 1000 mm.\u003c\/p\u003e\u003cp\u003eOne design covers several signal types: \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, \u003cstrong\u003eCANopen\u003c\/strong\u003e according to CiA 404, or the version without a transmitter with connections directly on the plug. The HART transmitter is set with the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number \u003cstrong\u003e01310-00220\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003eThe input has \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in classes A, B, and AA. The measuring range extends from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e, the smallest span is \u003cstrong\u003e50 K\u003c\/strong\u003e. The total accuracy via HART is \u003cstrong\u003e0.3% of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e resolution and 10 measurements per second, via CANopen at \u003cstrong\u003e±0.1 K\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlease note before ordering:\u003c\/strong\u003e The datasheet does not mention a hygiene approval. The sheet describes the sensor as hygienic but does not document EHEDG or 3-A, no surface roughness Ra, no information on cleanability, no sealing materials, and no FDA conformity; only material 1.4571 and the G1\/2\" hygienic process connection are confirmed – those who need approval must request it from the manufacturer. The ambient temperature is not the medium temperature: The medium can be up to +200 °C, the electronics in the head tolerate only -20 … +80 °C with a transmitter, and -30 … +100 °C without a transmitter. For CANopen, only the eight-pin connector is suitable because the CAN bus pinout requires five pins – shield, plus, ground, CAN High, and CAN Low. The CANopen transmitter is calibrated at the factory; only the HART transmitter can be adjusted later. When communicating via a HART modem, a resistance of \u003cstrong\u003e250 Ω\u003c\/strong\u003e must be considered. The sheet does not mention a CE mark, a directive, or a declaration of conformity; explosion protection is also not documented.\u003c\/p\u003e\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eProcess connection G1\/2\" hygienic or immersion probe\u003c\/li\u003e\n\n\u003cli\u003eSensor tube, connection and housing continuously made of stainless steel 1.4571\u003c\/li\u003e\n\n\u003cli\u003eConnector insert always metal, no plastic on the device\u003c\/li\u003e\n\n\u003cli\u003e4 … 20 mA with HART or CANopen according to CiA 404\u003c\/li\u003e\n\n\u003cli\u003eTotal accuracy 0.3% of the range at 16 bit, measuring range -50 to +200 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon GmbH","offers":[{"title":"Default Title","offer_id":57356934775110,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TPMG_produkt_4fda4d2f-f426-4e8b-8bdc-5938eddb5541.webp?v=1789243718","url":"https:\/\/octogon-sensors.com\/en\/products\/tpmg-hygiene-temperatursensor-hart-mhy-ts","provider":"octogon GmbH","version":"1.0","type":"link"}