{"product_id":"eome-zweikanaliger-io-link-messumformer","title":"EOME two-channel IO-Link transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eEOME\u003c\/strong\u003e is a two-channel IO-Link transducer as an OEM board, type \u003cstrong\u003eMEUT-E\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e measures a strain gauge full bridge, \u003cstrong\u003eChannel 2\u003c\/strong\u003e a temperature sensor – and both measured values are transmitted via a common IO-Link interface. This is the case for which this board is built: force or pressure and the corresponding temperature from one device, with one cable and one master port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe universal channel does not support strain gauge bridges.\u003c\/strong\u003e The datasheet lists them in the sensor list, but states below that strain gauge applications for the universal channel are not yet supported. If you need \u003cem\u003etwo\u003c\/em\u003e force channels, you cannot use this board for that today.\u003c\/p\u003e\n\u003cp\u003eChannel 1 accepts a \u003cstrong\u003estrain gauge full bridge\u003c\/strong\u003e from 350 Ω, with two bridges at least 2 × 700 Ω, with a bridge supply of \u003cstrong\u003e3 V\u003c\/strong\u003e; the unit of measurement is dimensionless. Channel 2 is preset to °C and accepts \u003cstrong\u003ePt100\u003c\/strong\u003e in a 3-wire circuit from -200 to 800 °C at 0.9 mA sensor current or a \u003cstrong\u003ethermocouple\u003c\/strong\u003e of type J (-210 ... 1200 °C), type K (-200 ... 1372 °C) or type N (-200 ... 1300 °C). The measuring range of both channels can be freely set in the range -3200.0 ... +3200.0.\u003c\/p\u003e\n\u003cp\u003eThe resolution is \u003cstrong\u003e16 bit on the strain gauge channel and 24 bit on the universal channel\u003c\/strong\u003e, the accuracy max. \u003cstrong\u003e0.05% of the measuring range\u003c\/strong\u003e plus sensor error. The filters are separate: 0.5 s for strain gauge, 25 s for temperature. The power-on delay is less than 5 s, the response time is 20 ms. The board is supplied with \u003cstrong\u003e24 VDC\u003c\/strong\u003e at less than 30 mA in standard operation, maximum 130 mA total current; reverse polarity is protected.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e40 × 17 × 8.25 mm\u003c\/strong\u003e and weighs about 6.5 g. The height comes from the construction: It consists of \u003cstrong\u003etwo stacked boards\u003c\/strong\u003e. The single-channel version with the same outline is only 4.5 mm high. Material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, installation position arbitrary, operating range \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the appropriate IODD file from the IODD Finder. The board has \u003cstrong\u003eIP00\u003c\/strong\u003e and must be installed in a housing. It has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007 + A1:2011. A CE mark is not documented in the manufacturer's datasheet; a declaration of conformity must be requested before placing it on the market in the EU. A version with integrated safety function PL c \/ SIL 1 is the \u003cstrong\u003eEOMF\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding the price:\u003c\/strong\u003e The price is for the board in its basic version. The measuring ranges of both channels are freely adjustable via IO-Link, so factory programming is not required. However, if you wish to have the board \u003cstrong\u003eprogrammed to your measuring ranges at the factory\u003c\/strong\u003e, this is possible at an additional cost — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us about it\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eTwo channels on one board: strain gauge full bridge and temperature sensor\u003c\/li\u003e\n\n\u003cli\u003eChannel 2 for Pt100 (3-wire) or thermocouple type J, K and N\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit on the strain gauge channel, 24 bit on the universal channel\u003c\/li\u003e\n\n\u003cli\u003eAccuracy max. 0.05% of the measuring range\u003c\/li\u003e\n\n\u003cli\u003eSeparate filters: 0.5 s for strain gauge, 25 s for temperature\u003c\/li\u003e\n\n\u003cli\u003eBoth measured values via one IO-Link interface\u003c\/li\u003e\n\n\u003cli\u003e40 × 17 × 8.25 mm, two stacked boards, approx. 6.5 g\u003c\/li\u003e\n\n\u003cli\u003eOperating range -20 ... +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306259030342,"sku":null,"price":134.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOME_MEUT-E_titelbild_961c1f67-c557-4ccc-a316-d76c0bc0d343.webp?v=1788951931","url":"https:\/\/octogon-sensors.com\/en\/products\/eome-two-channel-io-link-transmitter","provider":"octogon GmbH","version":"1.0","type":"link"}