{"title":"OEM Boards for Temperature","description":"\u003ch2\u003eOEM boards for temperature sensors\u003c\/h2\u003e \u003cp\u003eTransmitter modules without a housing, for installation in your own device. They take the signal of a resistance thermometer or a thermocouple – Pt100 and Pt1000 in 2-, 3- or 4-wire connection, thermocouples of types J, K and N – and pass the measured value on in analogue form or via IO-Link.\u003c\/p\u003e \u003cp\u003eThe modules listed here are of universal design and, depending on the type, can equally evaluate a strain gauge full bridge. They therefore also appear under \u003ca href=\"\/en\/collections\/oem-platinen-waegetransmitter\"\u003eOEM boards for weighing\u003c\/a\u003e. On single-channel versions the input is fixed to one sensor type when the order is placed.\u003c\/p\u003e","products":[{"product_id":"eoma-matu","title":"EOMA Universal Transducers (MATU)","description":"\u003cp\u003eThe \u003cstrong\u003eEOMA\u003c\/strong\u003e is a programmable universal transducer as an OEM board, type \u003cstrong\u003eMATU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOne board covers seven sensor types: It converts the signal from a temperature, force, or pressure sensor into a standardized analog signal for control. The sensor type and measuring range are programmed, meaning one item in stock replaces several specialized transducers.\u003c\/p\u003e\n\u003cp\u003eInputs include \u003cstrong\u003ePt100 and Pt1000\u003c\/strong\u003e in 4-, 3- or 2-wire circuits (sensor current 0.25 mA), \u003cstrong\u003ethermocouples of types J, K, and N\u003c\/strong\u003e, a \u003cstrong\u003estrain gauge full bridge\u003c\/strong\u003e from 350 Ω (bridge excitation 1.25 VDC for 2-wire, 3 VDC for 3-wire), \u003cstrong\u003ecurrent and voltage\u003c\/strong\u003e with 0 … 20 mA, 0 … 1 V and 0 … 10 V, and a \u003cstrong\u003epotentiometer\u003c\/strong\u003e from 350 Ω to 100 kΩ. Three digital inputs and outputs with 3.3 V \/ 2 mA are available as an option.\u003c\/p\u003e\n\u003cp\u003eOutputs are \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e in 2- or 3-wire circuits or \u003cstrong\u003e0 … 10 V\u003c\/strong\u003e, optionally as 0.5 … 10.5 V or 2 … 10 V. The resolution is \u003cstrong\u003e24 bit\u003c\/strong\u003e, the accuracy is \u003cstrong\u003emax. 0.1 % of the nominal range\u003c\/strong\u003e plus sensor error. A fault signal indicates short circuit and under-range with less than 3.6 mA and sensor break with over 21 mA. The filter is adjustable from 5 to 5000 ms.\u003c\/p\u003e\n\u003cp\u003eThe rectangular form factor measures \u003cstrong\u003e35 × 18 × 4 mm\u003c\/strong\u003e, the round form factor \u003cstrong\u003e31.4 × 28.6 × 4.8 mm\u003c\/strong\u003e with an Ø 8 mm hole; changing the form factor is not a one-to-one replacement as the solder pads are arranged differently. The weight is approx. 3.5 g, the operating range is \u003cstrong\u003e-40 … +85 °C\u003c\/strong\u003e. The board is powered with 9 … 35 VDC on the current output and 12 … 35 VDC on the voltage output; reverse polarity is protected, the short-circuit current is fixed.\u003c\/p\u003e\n\u003cp\u003eThe board is rated \u003cstrong\u003eIP00\u003c\/strong\u003e and must be installed in an enclosure. It is tested according to EN 61000-6-2:2019-11 and EN 61000-6-4:2020-09. A CE mark is not documented in the manufacturer's datasheet; a declaration of conformity must be requested before placing on the market in the EU. For hazardous areas, the \u003cstrong\u003eEOMB\u003c\/strong\u003e version with ATEX and IECEx certification is available. The DEV-KMA configurator with TrComm software is used for configuration and calibration.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eA programmable transducer for Pt100, Pt1000, thermocouple, strain gauge, current, voltage, and potentiometer\u003c\/li\u003e\n\n\u003cli\u003eResolution 24 bit, accuracy max. 0.1 % of the nominal range\u003c\/li\u003e\n\n\u003cli\u003eOutput 4 … 20 mA or 0 … 10 V in several ranges\u003c\/li\u003e\n\n\u003cli\u003eRectangular form factor 35 × 18 × 4 mm, round form factor 31.4 × 28.6 × 4.8 mm\u003c\/li\u003e\n\n\u003cli\u003eOperating range -40 … +85 °C, weight approx. 3.5 g\u003c\/li\u003e\n\n\u003cli\u003eFault signal for sensor break and range violation\u003c\/li\u003e\n\n\u003cli\u003eFilter 5 … 5000 ms adjustable\u003c\/li\u003e\n\n\u003cli\u003eEx-version available as EOMB\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306231701830,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMA_MATU_titelbild_48f0e73a-7129-4c08-9018-d5a1a951cf3d.webp?v=1788951905"},{"product_id":"eomb-matu-ex","title":"EOMB Universal Transmitter Ex (MATU-Ex)","description":"\u003cp\u003eThe \u003cstrong\u003eEOMB\u003c\/strong\u003e is the explosion-proof version of the universal transducer, type \u003cstrong\u003eMATU-Ex\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectrically, it is the same programmable transducer as the \u003cstrong\u003eEOMA\u003c\/strong\u003e, additionally certified as an \u003cstrong\u003eintrinsically safe Ex-component\u003c\/strong\u003e for zones 0, 1 and 2 for gases. The marking is \u003cstrong\u003eII 1 G Ex ia [ia] IIC Ga\u003c\/strong\u003e and \u003cstrong\u003eII 2 G Ex ia [ib] IIC Gb\u003c\/strong\u003e; the certificates are TÜV 21 ATEX 309041 U and IECEx TUN 22.0017 U.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eU\u003c\/strong\u003e in both certificate numbers means component, not device: The installer is responsible for the approval of the finished device. This includes four installation requirements – the board must be installed to at least \u003cstrong\u003eIP20\u003c\/strong\u003e according to DIN EN 60529, encapsulated according to DIN EN 60079-11 in such a way that the permissible barrier layer temperature of the Z-diodes is not exceeded, the supply and output circuit must be safely galvanically isolated from earth potential, and installation and commissioning must be carried out by qualified personnel with knowledge of the types of protection. A temperature class is not specified; it only results from the installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor Ex operation, a narrower operating temperature applies than in the general data:\u003c\/strong\u003e -40 ... +75 °C at the current output and -40 ... +50 °C at the voltage output, compared to a working range of -40 ... +85 °C. Anyone who relies on the approval must design according to these values. The intrinsic safety characteristics: Ui 30 VDC, Ii 110 mA, Pi 1 W at the input; Uo 4.1 V, Io 51 mA or 52 mA, Po 52 mW in the sensor circuit; Uo 12.6 V, Io 48 mA, Po 148 mW at the voltage output.\u003c\/p\u003e\n\u003cp\u003eThe input supports \u003cstrong\u003ePt100 and Pt1000\u003c\/strong\u003e in 4-, 3- or 2-wire circuits, \u003cstrong\u003ethermocouples of types J, K and N\u003c\/strong\u003e, a \u003cstrong\u003estrain gauge full bridge\u003c\/strong\u003e from 350 Ω, current and voltage, as well as a potentiometer from 350 Ω to 100 kΩ. The output is \u003cstrong\u003e4 ... 20 mA\u003c\/strong\u003e or \u003cstrong\u003e0 ... 10 V\u003c\/strong\u003e. The resolution is \u003cstrong\u003e24 bit\u003c\/strong\u003e, the accuracy max. 0.1 % of the nominal range. The rectangular design measures \u003cstrong\u003e35 × 18 × 4 mm\u003c\/strong\u003e, the round one 31.4 × 28.6 × 4.8 mm.\u003c\/p\u003e\n\u003cp\u003eThe intrinsically safe circuit requires an \u003cstrong\u003eisolation barrier\u003c\/strong\u003e in the safe area, which supplies the power and output circuit; it is not included in the scope of delivery. A CE mark is not documented in the manufacturer's data sheet; a declaration of conformity must be requested before placing it on the market in the EU. The DEV-KMA configurator with TrComm software is used for configuration.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eIntrinsically safe Ex-component for zones 0, 1 and 2 for gases\u003c\/li\u003e\n\n\u003cli\u003eATEX TÜV 21 ATEX 309041 U and IECEx TUN 22.0017 U\u003c\/li\u003e\n\n\u003cli\u003eA single transducer for Pt100, Pt1000, thermocouple, strain gauge, current, voltage, potentiometer\u003c\/li\u003e\n\n\u003cli\u003eResolution 24 bit, accuracy max. 0.1 % of nominal range\u003c\/li\u003e\n\n\u003cli\u003eOutput 4 ... 20 mA or 0 ... 10 V\u003c\/li\u003e\n\n\u003cli\u003eOnly 35 × 18 × 4 mm, round design 31.4 × 28.6 × 4.8 mm available\u003c\/li\u003e\n\n\u003cli\u003eEx operating temperature -40 ... +75 °C at current output, -40 ... +50 °C at voltage output\u003c\/li\u003e\n\n\u003cli\u003eVersion without Ex protection available as EOMA\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306239369542,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMB_MATU-Ex_titelbild_eb514156-a269-47f0-abec-74c221d181f1.webp?v=1788951905"},{"product_id":"eome-meut-e","title":"EOME 2-channel measuring transducers (MEUT-E)","description":"\u003cp\u003eThe \u003cstrong\u003eEOME\u003c\/strong\u003e is a two-channel IO-Link transducer as an OEM board, type \u003cstrong\u003eMEUT-E\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e measures a strain gauge full bridge, \u003cstrong\u003eChannel 2\u003c\/strong\u003e a temperature sensor – and both measured values are transmitted via a common IO-Link interface. This is the case for which this board is built: force or pressure and the corresponding temperature from one device, with one cable and one master port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe universal channel does not support strain gauge bridges.\u003c\/strong\u003e The datasheet lists them in the sensor list, but states below that strain gauge applications for the universal channel are not yet supported. If you need \u003cem\u003etwo\u003c\/em\u003e force channels, you cannot use this board for that today.\u003c\/p\u003e\n\u003cp\u003eChannel 1 accepts a \u003cstrong\u003estrain gauge full bridge\u003c\/strong\u003e from 350 Ω, with two bridges at least 2 × 700 Ω, with a bridge supply of \u003cstrong\u003e3 V\u003c\/strong\u003e; the unit of measurement is dimensionless. Channel 2 is preset to °C and accepts \u003cstrong\u003ePt100\u003c\/strong\u003e in a 3-wire circuit from -200 to 800 °C at 0.9 mA sensor current or a \u003cstrong\u003ethermocouple\u003c\/strong\u003e of type J (-210 ... 1200 °C), type K (-200 ... 1372 °C) or type N (-200 ... 1300 °C). The measuring range of both channels can be freely set in the range -3200.0 ... +3200.0.\u003c\/p\u003e\n\u003cp\u003eThe resolution is \u003cstrong\u003e16 bit on the strain gauge channel and 24 bit on the universal channel\u003c\/strong\u003e, the accuracy max. \u003cstrong\u003e0.05% of the measuring range\u003c\/strong\u003e plus sensor error. The filters are separate: 0.5 s for strain gauge, 25 s for temperature. The power-on delay is less than 5 s, the response time is 20 ms. The board is supplied with \u003cstrong\u003e24 VDC\u003c\/strong\u003e at less than 30 mA in standard operation, maximum 130 mA total current; reverse polarity is protected.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e40 × 17 × 8.25 mm\u003c\/strong\u003e and weighs about 6.5 g. The height comes from the construction: It consists of \u003cstrong\u003etwo stacked boards\u003c\/strong\u003e. The single-channel version with the same outline is only 4.5 mm high. Material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, installation position arbitrary, operating range \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the appropriate IODD file from the IODD Finder. The board has \u003cstrong\u003eIP00\u003c\/strong\u003e and must be installed in a housing. It has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007 + A1:2011. A CE mark is not documented in the manufacturer's datasheet; a declaration of conformity must be requested before placing it on the market in the EU. A version with integrated safety function PL c \/ SIL 1 is the \u003cstrong\u003eEOMF\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding the price:\u003c\/strong\u003e The price is for the board in its basic version. The measuring ranges of both channels are freely adjustable via IO-Link, so factory programming is not required. However, if you wish to have the board \u003cstrong\u003eprogrammed to your measuring ranges at the factory\u003c\/strong\u003e, this is possible at an additional cost — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us about it\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eTwo channels on one board: strain gauge full bridge and temperature sensor\u003c\/li\u003e\n\n\u003cli\u003eChannel 2 for Pt100 (3-wire) or thermocouple type J, K and N\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit on the strain gauge channel, 24 bit on the universal channel\u003c\/li\u003e\n\n\u003cli\u003eAccuracy max. 0.05% of the measuring range\u003c\/li\u003e\n\n\u003cli\u003eSeparate filters: 0.5 s for strain gauge, 25 s for temperature\u003c\/li\u003e\n\n\u003cli\u003eBoth measured values via one IO-Link interface\u003c\/li\u003e\n\n\u003cli\u003e40 × 17 × 8.25 mm, two stacked boards, approx. 6.5 g\u003c\/li\u003e\n\n\u003cli\u003eOperating range -20 ... +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306259030342,"sku":null,"price":134.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOME_MEUT-E_titelbild_961c1f67-c557-4ccc-a316-d76c0bc0d343.webp?v=1788951931"},{"product_id":"eomf-meuts-sil","title":"EOMF 2-channel measuring transducer PL c (MEUTS-SIL)","description":"\u003cp\u003eThe \u003cstrong\u003eEOMF\u003c\/strong\u003e is a two-channel measuring transducer with a built-in overload circuit of level \u003cstrong\u003ePL c \/ SIL 1\u003c\/strong\u003e, type \u003cstrong\u003eMEUTS-SIL\u003c\/strong\u003e, certified by TÜV Nord under number 44 799 14098202.\u003c\/p\u003e\n\u003cp\u003eIts special feature is the safety circuit: it has its \u003cstrong\u003eown amplifier\u003c\/strong\u003e and runs \u003cstrong\u003eparallel\u003c\/strong\u003e to the measurement chain of the IO-Link transducer – meaning the safety function is not dependent on the measurement chain. A solid-state relay opens if the switching point is exceeded, if the measuring amplifier's supply voltage is too low or missing, if there is a cable break on one or both signal lines, and if the safety circuit's own supply is too low or missing. \u003cstrong\u003eThe safe state is the open relay.\u003c\/strong\u003e The input is high-impedance biased to detect a cable break; two comparators – one for the measuring signal against the switching point, one for the bridge supply – are AND-linked.\u003c\/p\u003e\n\u003cp\u003eTwo \u003cstrong\u003elimit values\u003c\/strong\u003e can be set via IO-Link: the turn-on point from -7 to +7 mV, the turn-off point from -5 to +21 mV, with a switching accuracy of ± 50 µV and a \u003cstrong\u003ereaction time of a maximum of 10 ms\u003c\/strong\u003e. The switching load is a maximum of 30 VAC\/VDC at 500 mA. It is based on EN ISO 13849-1:2015 and EN 61508:2010.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChannel 1\u003c\/strong\u003e measures a full strain gauge bridge, dimensionless, from 350 Ω (two bridges from 2 × 700 Ω) with a bridge supply of 3 V. \u003cstrong\u003eChannel 2\u003c\/strong\u003e is universal, pre-set to °C, for \u003cstrong\u003ePt100\u003c\/strong\u003e in 3-wire circuit from -200 to 800 °C at 0.9 mA or a \u003cstrong\u003ethermocouple\u003c\/strong\u003e of type J (-210 … 1200 °C), type K (-200 … 1372 °C) or type N (-200 … 1300 °C). The range of both channels is freely adjustable in the range -3200.0 … +3200.0.\u003c\/p\u003e\n\u003cp\u003eThe output provides \u003cstrong\u003eIO-Link\u003c\/strong\u003e with level 0 \/ 24 V \u003cstrong\u003eand\u003c\/strong\u003e a current output \u003cstrong\u003e4 … 20 mA\u003c\/strong\u003e, which runs via input 1. The resolution is 16 bit on the strain gauge channel and 24 bit on the universal channel, with an accuracy of max. 0.05 % of the measuring range plus sensor error. Filter: 0.5 s for strain gauge, 25 s for temperature. Supply \u003cstrong\u003e24 VDC\u003c\/strong\u003e at under 30 mA in standard operation, maximum 130 mA total current.\u003c\/p\u003e\n\u003cp\u003eThe board measures \u003cstrong\u003e21 × 76.95 × 4.2 mm\u003c\/strong\u003e and weighs approximately 7.6 g, material FR4 and PBT, connection via solder pads 2.7 × 1.5 mm, mounting position optional, operating range \u003cstrong\u003e-20 °C to +80 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree mounting requirements and the enabling of the limit values must be read before the housing is closed.\u003c\/strong\u003e The board must be installed in the sensor housing to at least \u003cstrong\u003eIP54\u003c\/strong\u003e and protected against vibrations; the safety circuit must be regularly checked for function, the manufacturer recommends \u003cstrong\u003etwo years\u003c\/strong\u003e, and the limit values must be checked before commissioning. To set the limit values via IO-Link, a \u003cstrong\u003ephototransistor\u003c\/strong\u003e (SFH 309 or similar) must be connected and illuminated; thereafter, the settings must be read back and the phototransistor darkened – in normal operation, it must be covered in such a way that unintentional illumination is excluded.\u003c\/p\u003e\n\u003cp\u003eAn \u003cstrong\u003eIO-Link master\u003c\/strong\u003e is required for configuration and operation, as well as the IODD file from the IODD finder. The board has been tested according to EN 61000-6-2:2005 and EN 61000-6-4:2007. A CE mark is not documented in the manufacturer's data sheet; a declaration of conformity must be requested before placing on the market in the EU. The version without safety function is the \u003cstrong\u003eEOME\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegarding price:\u003c\/strong\u003e The price applies to the basic version of the board. Measuring ranges and limit values are adjustable via IO-Link, so factory programming is not required. If you would like the board \u003cstrong\u003efactory-programmed to your measuring ranges and switching points\u003c\/strong\u003e, this is possible at an additional cost — \u003ca href=\"\/en\/pages\/contact\"\u003eplease ask us\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003eOverload circuit PL c \/ SIL 1, TÜV Nord 44 799 14098202\u003c\/li\u003e\n\n\u003cli\u003eSafety circuit with its own amplifier, parallel to the measuring chain\u003c\/li\u003e\n\n\u003cli\u003eRelay also opens in case of cable break and undervoltage – safe state is open\u003c\/li\u003e\n\n\u003cli\u003eTwo limit values adjustable via IO-Link, reaction time max. 10 ms\u003c\/li\u003e\n\n\u003cli\u003eOutputs IO-Link and 4 … 20 mA\u003c\/li\u003e\n\n\u003cli\u003eChannel 1 full strain gauge bridge, Channel 2 Pt100 or thermocouple\u003c\/li\u003e\n\n\u003cli\u003eResolution 16 bit strain gauge, 24 bit universal, accuracy max. 0.05 %\u003c\/li\u003e\n\n\u003cli\u003e21 × 76.95 × 4.2 mm, approx. 7.6 g, operating range -20 … +80 °C\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57306259620166,"sku":null,"price":369.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/EOMF_MEUTS-SIL_titelbild_b1ff3cac-f6c1-4f9f-be9f-e3eea90af3e2.webp?v=1788951931"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/collections\/blog-io-link-temperatur-transmitter.webp?v=1789446833","url":"https:\/\/octogon-sensors.com\/en\/collections\/temperaturtransmitter-oem-platinen.oembed","provider":"octogon GmbH","version":"1.0","type":"link"}