{"title":"Temperature Sensors, analogue 4…20 mA","description":"\u003ch2\u003eTemperature sensors with an analogue output\u003c\/h2\u003e \u003cp\u003eA resistance thermometer delivers ohms, a thermocouple millivolts – a control system can do nothing directly with either. The sensors here already carry the transmitter in the terminal head and output \u003cstrong\u003e4…20 mA\u003c\/strong\u003e: immune to interference over long cables, no software needed, into any free analogue input.\u003c\/p\u003e \u003cp\u003eSome of the devices superimpose a \u003cstrong\u003eHART\u003c\/strong\u003e signal on the current. The analogue output stays exactly as it is, while configuration, adjustment and diagnostics run over the same two wires. For measuring points without a cable route see the \u003ca href=\"\/en\/collections\/temperatur-funk-tf\"\u003ewireless sensors\u003c\/a\u003e. Anyone who prefers a passive sensor and a separate transmitter will find those under \u003ca href=\"\/en\/collections\/temperaturmessumformer\"\u003etemperature transmitters\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"tdma-infrarot-temperatursensor-mets-ir","title":"TIMA Infrared Temperature Sensor (METS-IR)","description":"\u003cp\u003eThe \u003cstrong\u003eTIMA\u003c\/strong\u003e is an infrared temperature sensor for non-contact measurement, manufacturer type Müller \u003cstrong\u003eMETS-IR\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt measures on moving, hot or delicate surfaces without touching the medium – where a protective tube would be in the way or cannot be installed at all. Housing, display and the two limit contacts are the same as on the screw-in sensors of the series.\u003c\/p\u003e\n\u003cp\u003eThe sensor evaluates infrared radiation in the spectral range \u003cstrong\u003e8 … 14 µm\u003c\/strong\u003e and covers \u003cstrong\u003e-40 … +1000 °C\u003c\/strong\u003e, with a minimum span of 100 °C. The optical resolution is \u003cstrong\u003e15:1\u003c\/strong\u003e. Accuracy is \u003cstrong\u003e±1.5 °C or ±1.5 %\u003c\/strong\u003e – whichever is greater applies – repeatability ±0.75 °C or ±0.75 %, resolution 0.1 K. Emissivity and transmissivity are adjustable from 0.100 to 1.100 in software. The response time is \u003cstrong\u003e30 ms\u003c\/strong\u003e (t90) at 10 measurements per second.\u003c\/p\u003e\n\u003cp\u003eThe output is \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in 3-wire technology, current range 3.8 … 20.5 mA, with a fault signal at 3.6 mA (short circuit) and 21 mA (break). Added to that: a 4-digit 7-segment display in the head, which rotates through \u003cstrong\u003e330°\u003c\/strong\u003e, and \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e, PNP or NPN, 30 VDC \/ 200 mA. Supply is \u003cstrong\u003e24 VDC ±10 %\u003c\/strong\u003e through an eight-pin M12×1 connector – the only connection on this product.\u003c\/p\u003e\n\u003cp\u003eMechanically: process connection from 1\/4\" to 1\" as well as 1\/4NPT to 1\/2NPT, protective tube in 1.4571, Ø 6 × 0.5 mm, 100 mm neck tube optional, PBT GF30 housing, stainless steel measuring head, weight approx. 240 g, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e with encapsulated boards. Vibration to IEC 68-2-6, shock to IEC 68-2-27.\u003c\/p\u003e\n\u003cp\u003eThree things belong in the planning. \u003cstrong\u003eThe measuring spot grows with distance\u003c\/strong\u003e – 6.5 mm at the front edge, 16.6 mm at 200 mm, 76.5 mm at one metre; the target must be at least as large as the spot. \u003cstrong\u003eThe ambient temperature is not the medium temperature\u003c\/strong\u003e – the electronics in the head tolerate -20 … +80 °C, the measuring head -20 … +120 °C. And this product measures against the \u003cstrong\u003eopen atmosphere\u003c\/strong\u003e, system pressure 0 bar; it does not belong in a pressurised space, whereas the other sensors of the series withstand PN 25. After 10 minutes of warm-up the reading is dependable.\u003c\/p\u003e\n\u003cp\u003eProgramming requires the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator with the TrComm software. No CE marking is documented in the manufacturer's data sheet, no declaration of conformity is available, and one must be requested before placing the product on the market in the EU. No explosion protection is documented.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact measurement from -40 to +1000 °C\u003c\/li\u003e\n\u003cli\u003eOptical resolution 15:1, spectral range 8 … 14 µm\u003c\/li\u003e\n\u003cli\u003eAccuracy ±1.5 °C or ±1.5 %, resolution 0.1 K\u003c\/li\u003e\n\u003cli\u003eResponse time 30 ms, 10 measurements per second\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA with HART, 3-wire\u003c\/li\u003e\n\u003cli\u003eDisplay in a head that rotates through 330°\u003c\/li\u003e\n\u003cli\u003eTwo limit contacts, PNP or NPN\u003c\/li\u003e\n\u003cli\u003eEmissivity adjustable in software\u003c\/li\u003e\n\u003cli\u003eProtection at least IP 65\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618635078,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TIMA_METS-IR_titelbild_c209e1a8-b964-4983-b7ef-4486cbc6379a.webp?v=1788951931"},{"product_id":"tdmb-thermoelement-temperatursensor-mets-ts","title":"TEMA Screw-in Temperature Sensor Type K (METS-TS)","description":"\u003cp\u003eThe \u003cstrong\u003eTEMA\u003c\/strong\u003e is a screw-in temperature sensor with a type K thermocouple, manufacturer type Müller \u003cstrong\u003eMETS-TS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt combines sensor, amplifier, display and two limit contacts in one housing: one device at the process connection, one signal to the control system, one value to read on site. A separate transmitter in the control cabinet becomes unnecessary.\u003c\/p\u003e\n\u003cp\u003eThe thermocouple is a \u003cstrong\u003etype K (NiCr-Ni)\u003c\/strong\u003e with a tolerance of \u003cstrong\u003e±1.5 °C to DIN EN 60584-2 class 1\u003c\/strong\u003e. The measuring range runs from \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e with a minimum span of 50 °C. Amplifier accuracy is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e resolution, the measuring rate 10 measurements per second, the response time 20 ms; the filter is adjustable from 0 to 99 s and the transfer characteristic is linear with temperature.\u003c\/p\u003e\n\u003cp\u003eThe output is \u003cstrong\u003e4 … 20 mA with a superimposed HART signal\u003c\/strong\u003e in the 2-wire current loop, current range 3.8 … 20.5 mA, fault signal 3.6 mA on short circuit and 21 mA on break. Supply is \u003cstrong\u003e12 … 40 VDC from the loop\u003c\/strong\u003e, with reverse polarity protection. Setting is done with the keys at the display or over HART. The \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e are PNP or NPN, 30 VDC \/ 200 mA, optionally 1000 mA.\u003c\/p\u003e\n\u003cp\u003eMechanically: process connection from 1\/4\" to 1\" as well as 1\/4NPT to 1\/2NPT, protective tube in \u003cstrong\u003e1.4571\u003c\/strong\u003e, Ø 6 × 0.5 mm, 100 mm neck tube optional, insertion lengths from 50 to 1000 mm, PBT GF30 housing, polycarbonate display top, system pressure \u003cstrong\u003ePN 25\u003c\/strong\u003e, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e with encapsulated boards, any mounting position.\u003c\/p\u003e\n\u003cp\u003eTwo points for sizing. \u003cstrong\u003eThe ambient temperature is not the medium temperature.\u003c\/strong\u003e The medium may reach +200 °C, the electronics in the head only -20 … +80 °C – the manufacturer states explicitly for this series that temperatures above +85 °C can destroy the electronics. And: \u003cstrong\u003ewhich connector carries how many limit contacts is not a free choice.\u003c\/strong\u003e Ten connections are available, but two contacts are only possible on M12 five- and eight-pin, on MIL and on the cable version.\u003c\/p\u003e\n\u003cp\u003eProgramming requires the \u003cstrong\u003eDEV-KMA\u003c\/strong\u003e configurator with the TrComm software. No CE marking is documented in the manufacturer's data sheet and no declaration of conformity is available. The Ex version of this design is the \u003cstrong\u003eTEMD\u003c\/strong\u003e (METS-WTEx).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType K thermocouple, ±1.5 °C to DIN EN 60584-2 class 1\u003c\/li\u003e\n\u003cli\u003eMedium -50 to +200 °C, minimum span 50 °C\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA with HART in the 2-wire loop\u003c\/li\u003e\n\u003cli\u003eAccuracy 0.3 % of the range, 16 bit\u003c\/li\u003e\n\u003cli\u003eDisplay and keys on the device, plus HART\u003c\/li\u003e\n\u003cli\u003eTwo limit contacts, PNP or NPN\u003c\/li\u003e\n\u003cli\u003eProtective tube 1.4571, insertion lengths 50 to 1000 mm\u003c\/li\u003e\n\u003cli\u003eSystem pressure PN 25, protection at least IP 65\u003c\/li\u003e\n\u003cli\u003eTen electrical connections to choose from\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618667846,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TEMA_METS-TS_titelbild_749e8a5d-fb95-407c-8fd9-f49a7fb5ec98.webp?v=1788951931"},{"product_id":"tpma-kompakt-temperatursensor-mits","title":"TRMA Room Temperature Sensor HART (MITS)","description":"\u003cp\u003eThe \u003cstrong\u003eTRMA\u003c\/strong\u003e is a room temperature sensor, manufacturer type Müller \u003cstrong\u003eMITS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is built for air-conditioning and cold storage – refrigeration plants on ships, cold rooms, building services. The housing is screwed to the wall, the short protective tube reaches into the room. Two versions are available: the sensing element sits either \u003cstrong\u003edirectly on the connector\u003c\/strong\u003e – the sensor then outputs its resistance – or behind a \u003cstrong\u003eHART transmitter\u003c\/strong\u003e that turns it into 4 … 20 mA.\u003c\/p\u003e\n\u003cp\u003eThe input takes \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire connection, in classes \u003cstrong\u003eA, B and AA\u003c\/strong\u003e. With an amplifier, one Pt100 is provided for. The measuring range runs \u003cstrong\u003ewithout\u003c\/strong\u003e an amplifier from -30 to \u003cstrong\u003e+90 °C\u003c\/strong\u003e, \u003cstrong\u003ewith\u003c\/strong\u003e an amplifier from -30 to \u003cstrong\u003e+80 °C\u003c\/strong\u003e at a smallest span of 50 K – the same difference applies to the working temperature of the device.\u003c\/p\u003e\n\u003cp\u003eThe current output delivers \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, overall range 3.6 … 21 mA, with 21 mA on break, short circuit or underrange. Total error is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e resolution, the measuring rate 10 measurements per second, the filter 0 … 99 s. Setting is done in software over HART: LRL, URL, LRV, URV, filter, adjustment and simulation. Supply comes from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e, load R = (UB − 12 V) \/ 21 mA, with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003eMechanically: \u003cstrong\u003ePBT GF30\u003c\/strong\u003e housing in black, flammability UL94 HB, dimensions approx. \u003cstrong\u003e117 × 28 × 32 mm\u003c\/strong\u003e, fastening through two Ø 4.6 mm holes 45.5 mm apart, weight 50 g, any mounting position. The \u003cstrong\u003eprotective tube is fixed at 30 mm and Ø 6 mm\u003c\/strong\u003e – other lengths are not documented. Protection is at least \u003cstrong\u003eIP 65\u003c\/strong\u003e but depends on the chosen connection; the manufacturer gives no assignment. Ten connections are available, from M12×1 to a cable outlet – two sensors do not fit every connector.\u003c\/p\u003e\n\u003cp\u003eConfiguration uses the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e; when communicating through a HART modem a minimum resistance of 250 Ω has to be taken into account. No CE marking is documented in the manufacturer's data sheet and no declaration of conformity is available. UL94 HB is the lowest grade in the series.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoom sensor for cold rooms, air-conditioning and building services\u003c\/li\u003e\n\u003cli\u003ePt100 or Pt1000, classes A, B and AA\u003c\/li\u003e\n\u003cli\u003eTwo versions: resistance direct or 4 … 20 mA with HART\u003c\/li\u003e\n\u003cli\u003eRange -30 to +90 °C without, -30 to +80 °C with amplifier\u003c\/li\u003e\n\u003cli\u003eTotal error 0.3 % of the range, 16 bit\u003c\/li\u003e\n\u003cli\u003ePBT GF30 housing, only 50 g, wall fixing 45.5 mm\u003c\/li\u003e\n\u003cli\u003eProtective tube 30 mm, Ø 6 mm\u003c\/li\u003e\n\u003cli\u003eProtection at least IP 65\u003c\/li\u003e\n\u003cli\u003eSetting in software over HART\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618700614,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TRMA_MITS_titelbild_7b20f2eb-2ab1-419e-b0c7-e315d0f60e35.webp?v=1788951931"},{"product_id":"temperatursensor-magnetisch-mets-wtm","title":"TMMB Magnetic Surface Temperature Sensor (METS-WTM)","description":"\u003cp\u003eThe \u003cstrong\u003eTMMB\u003c\/strong\u003e is a surface temperature sensor on a holding magnet, manufacturer type Müller \u003cstrong\u003eMETS-WTM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is placed on a pipe or a vessel and holds itself – no drilling, no process connection, no intervention in the medium. The spring-loaded measuring face presses against the surface, the magnet pulls with \u003cstrong\u003e66 N\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis device has no display and no keys\u003c\/strong\u003e – it is set exclusively over HART. Otherwise it is identical to the \u003cstrong\u003eTMMA\u003c\/strong\u003e (METS-WSM), which carries the display. Anyone who wants to read the value on site orders the TMMA.\u003c\/p\u003e\n\u003cp\u003eThe input is a \u003cstrong\u003ePt100 in 4-wire connection\u003c\/strong\u003e in classes A, B and AA (B 1\/3 DIN), with a range of \u003cstrong\u003e-50 … +200 °C\u003c\/strong\u003e at a smallest span of 50 K; up to -50 … +250 °C on request. The output is \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop, current range 3.8 … 20.5 mA, with 3.6 mA on short circuit and 21 mA on break. Accuracy is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e, the response time 20 ms, the measuring rate 10 measurements per second, the filter 0 … 99 s.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etwo limit contacts\u003c\/strong\u003e are PNP or NPN with 30 VDC \/ 200 mA, optionally 1000 mA; switching point and hysteresis are adjustable across the whole measuring range, the switching delay from 0.0 to 999.9 s, and failsafe behaviour as well. Supply comes from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e, load R = (UB − 12 V) \/ 21 mA, with reverse polarity protection.\u003c\/p\u003e\n\u003cp\u003eMechanically: holding magnet in \u003cstrong\u003eAlnico 500\u003c\/strong\u003e, measuring face Ø 6 mm spring-loaded with 1.5 mm travel, sensor body stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, PBT GF30 housing, connection either at the side or on top, weight approx. 259 g, system pressure PN 25, protection at least \u003cstrong\u003eIP 65\u003c\/strong\u003e at the electronics.\u003c\/p\u003e\n\u003cp\u003eThree points the manufacturer leaves open and that belong in the planning. \u003cstrong\u003eThe sensor sits with the magnet directly on the hot surface.\u003c\/strong\u003e The measuring face may reach +200 °C, the electronics in the head only +80 °C – how much heat travels into the head is not documented, and above +85 °C the electronics can be destroyed. The \u003cstrong\u003egalvanic isolation applies only between the switching outputs and the amplifier\u003c\/strong\u003e, not against the loop and not against the surface the magnet sits on. And how the \u003cstrong\u003eholding force changes with temperature\u003c\/strong\u003e the source does not say.\u003c\/p\u003e\n\u003cp\u003eTen electrical connections are available – which one carries how many limit contacts is not a free choice: two contacts are only possible on M12 five- and eight-pin, on MIL and on the cable version; on Deutsch DT04 four-pin and on Super Seal, none. Configuration uses the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number 01310-00220; when communicating through a HART modem a resistance of 250 Ω has to be taken into account. No CE marking is documented and no declaration of conformity is available.\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring without intervening in the process – holding magnet with 66 N\u003c\/li\u003e\n\u003cli\u003eSpring-loaded measuring face Ø 6 mm, 1.5 mm travel\u003c\/li\u003e\n\u003cli\u003ePt100 4-wire, classes A, B and AA\u003c\/li\u003e\n\u003cli\u003eMedium -50 to +200 °C, up to +250 °C on request\u003c\/li\u003e\n\u003cli\u003e4 … 20 mA with HART, accuracy 0.3 % of the range\u003c\/li\u003e\n\u003cli\u003eTwo limit contacts with adjustable delay\u003c\/li\u003e\n\u003cli\u003eSensor body stainless steel 1.4571, magnet Alnico 500\u003c\/li\u003e\n\u003cli\u003eProtection at least IP 65\u003c\/li\u003e\n\u003cli\u003eVersion with display available as TMMA\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618766150,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TMMB_METS-WTM_titelbild_762e2e44-6288-4034-aa0b-09e27d501197.webp?v=1788951932"},{"product_id":"temperatursensor-feder-kontakt-mkts-sp","title":"TSMA Spring-loaded Contact Temperature Sensor (MKTS-SP)","description":"\u003cp\u003eThe \u003cstrong\u003eTSMA\u003c\/strong\u003e is a temperature sensor with a spring-loaded measuring tip, manufacturer type Müller \u003cstrong\u003eMKTS-SP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is built for bearing and surface temperatures: the spring presses the tip against the measuring point with \u003cstrong\u003e14 mm of travel\u003c\/strong\u003e and keeps contact even when the component moves or expands with heat. That is exactly what it is for – a rigidly screwed-in sensor loses contact at such a point.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis sensor does not withstand process pressure.\u003c\/strong\u003e The manufacturer says so in as many words: the process connection has no sealing effect. It measures at the surface and in the bearing, not inside a closed medium; the pressure equipment directive is therefore not applicable.\u003c\/p\u003e\n\u003cp\u003eThe input takes \u003cstrong\u003eone or two Pt100\u003c\/strong\u003e or \u003cstrong\u003ePt1000\u003c\/strong\u003e in 2-, 3- or 4-wire connection in classes A, B and AA, alternatively a \u003cstrong\u003etype K thermocouple with a cross-band\u003c\/strong\u003e. The range runs from \u003cstrong\u003e-50 … +150 °C\u003c\/strong\u003e at a smallest span of 50 K. As with the room sensor there are two versions: resistance directly on the connector, or \u003cstrong\u003e4 … 20 mA with HART\u003c\/strong\u003e in the 2-wire loop.\u003c\/p\u003e\n\u003cp\u003eTotal accuracy is \u003cstrong\u003e0.3 % of the range\u003c\/strong\u003e at \u003cstrong\u003e16 bit\u003c\/strong\u003e, the response time 20 ms, the measuring rate 10 measurements per second, the filter 0 … 99 s, the transfer characteristic linear with temperature. The current range is 3.8 … 20.5 mA with 3.6 mA on short circuit and 21 mA on break. Supply comes from the HART current loop with \u003cstrong\u003e12 … 40 VDC\u003c\/strong\u003e, load R = (UB − 12 V) \/ 21 mA, with reverse polarity protection. Setting is done in software over HART.\u003c\/p\u003e\n\u003cp\u003eMechanically: process connection 3\/8\", 1\/2\" or 3\/4\" without sealing effect, insertion length \u003cstrong\u003e45 or 65 mm\u003c\/strong\u003e as well as custom, sensor tube Ø 6 mm in stainless steel \u003cstrong\u003e1.4571\u003c\/strong\u003e, knurled screw 1.4541, compression spring in 1.4310 spring steel, PTFE insulating body, weight approx. 200 g. Protection is \u003cstrong\u003eIP 65 at the electronics and IP 68 at the sensor\u003c\/strong\u003e, encapsulated inside. Without a transmitter the ambient may be -20 … +100 °C, with a transmitter only -20 … +80 °C.\u003c\/p\u003e\n\u003cp\u003eTwo notes: the ambient temperature is not the medium temperature – which neck length or insulation a hot medium calls for, the source does not say. And the \u003cstrong\u003eMK product code is used three times by this manufacturer\u003c\/strong\u003e – MKTS, MKTS-GL and MKTS-SP, with a different meaning of the following digits in each case; when ordering, the type designation belongs in plain text, not just the code. Ten electrical connections are available; two sensors do not fit every connector.\u003c\/p\u003e\n\u003cp\u003eConfiguration uses the \u003cstrong\u003eHART interface with USB and software\u003c\/strong\u003e, order number 01310-00220. No CE marking is documented in the manufacturer's data sheet and no declaration of conformity is available for this version. The version with IO-Link is the \u003cstrong\u003eTSMB\u003c\/strong\u003e (MKTS-SPIO).\u003c\/p\u003e\n\u003ch3\u003eAdvantages at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSpring-loaded measuring tip, 14 mm ±1 mm of travel\u003c\/li\u003e\n\u003cli\u003eKeeps contact on moving and expanding components\u003c\/li\u003e\n\u003cli\u003ePt100, Pt1000 or type K thermocouple\u003c\/li\u003e\n\u003cli\u003eRange -50 to +150 °C, smallest span 50 K\u003c\/li\u003e\n\u003cli\u003eResistance direct or 4 … 20 mA with HART\u003c\/li\u003e\n\u003cli\u003eAccuracy 0.3 % of the range, 16 bit\u003c\/li\u003e\n\u003cli\u003eInsertion length 45 or 65 mm, sensor tube 1.4571\u003c\/li\u003e\n\u003cli\u003eIP 65 at the electronics, IP 68 at the sensor\u003c\/li\u003e\n\u003cli\u003eVersion with IO-Link available as TSMB\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"octogon Shop","offers":[{"title":"Default Title","offer_id":57245618831686,"sku":null,"price":0.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0819\/5558\/6374\/files\/TSMA_MKTS-SP_titelbild_2a57f779-2669-4376-8a67-3184cf076f1f.webp?v=1788951932"}],"url":"https:\/\/octogon-sensors.com\/en\/collections\/temperatursensoren-analog.oembed","provider":"octogon GmbH","version":"1.0","type":"link"}